贵州制冷设备施工安装三分产品质量七分施工态度

贵州制冷设备施工安装三分产品质量七分施工态度

发布日期:2018-04-11 作者:贵州制冷设备安装 点击:

贵州制冷设备施工安装三分产品质量七分施工态度

引言:冷库冷风机、温度控制器、控制线路、阀件、管路、冷库主机等合理的连接安装、正确的安装工艺才能使冷库机组、制冷系统安全稳定的工作。那么贵州制冷设备安装就和你聊聊冷库机组在安装的时候需要注意哪些问题呢?

Introduction: cold storage air cooler, temperature controller, control line, valve parts, piping, cold storage host and other reasonable connection installation, the correct installation process can make the cold storage unit and refrigeration system safe and stable work. What are the problems that the cold storage units need to pay attention to when they are installed?

贵州制冷设备安装

1、冷库机组安装冷库机组位置离蒸发器越近越好,且易维修,散热良好,如外移需安装遮雨棚,冷库机组位四角需要安放防震垫片,安装水平牢固,不易被人碰着。

1, the cold storage unit installed cold storage unit position from the evaporator is better, and easy to repair, good heat dissipation, such as the external shift need to install the canopy, cold storage unit position four angles need to place shock gaskets, installation level is firm, not easy to be met.

2、冷库机组铜管排放所有铜管需分别穿保温管与同方向电线一起用空调扎带一起包扎好,尽量走直管线并分段固定。

2. All copper pipes of copper pipe of cold storage unit need to be wrapped together with the same direction wire with the same direction wire together with the air conditioning band together, and try to take the straight line as far as possible and fix it piecewise.

贵州制冷设备

3、冷库机组散热器安装散热器安放位置离冷库机组越近越好,最好在冷库机组偏上位,散热器安装位具备最佳散热环境,吸风口不能对着其它设备出风口,特别是油性气体,出风口不能短路及对着别处窗口(特别是居民窗口)和设备,离地应有2M高,安装水平牢固。

3. The location of radiator installation in cold storage unit is better from the cold storage unit, better in the cold storage unit, preferably in the cold storage unit. The radiator installation position has the best heat dissipation environment, the suction outlet can not be exposed to other equipment, especially the oil gas, the outlet can not short circuit and facing other window (especially resident window). Equipment, from the ground should be 2M high, the installation level is strong.

4、冷库机组管路、线路安装:所有铜管焊接、试压、吹污完毕,安装保温管,注意使用胶水将保温材料的所有连接缝隙粘牢,用扎带包扎好,电线、电缆应单独使用线管或线槽保护,分段按规范设置固定支架。弱电信号线应与强电分开走线,必要时作好屏蔽处理。

4. Installation of line and line of cold storage unit: all copper pipe welding, test pressure, blow up, installation of insulation pipe, pay attention to glue all connection cracks of insulation material, bandage with bandage, wire and cable should be protected by line pipe or line slot alone, and set the fixed bracket according to rules. The weak signal line should be separated from the strong current and shielded if necessary.

5、因冷库机组、冷风机在厂里都经过打压密封,因此开封时,都应有压力,可查是否有漏,出厂铜管应两头有封尘措施,施工时也要注意随时密封,以防水、灰尘进入管内,冷凝器、冷库主机、冷风机使用铜管连接,以焊接方法,接口牢固美观。

5, the cold storage unit and cold air fan are sealed in the factory. Therefore, when the seal is opened, there should be pressure to find out whether there is leakage. The factory copper pipe should be sealed at any time in the construction. In the construction, the waterproof and dust will enter the pipe. The condenser, the cold storage host and the cold air fan are connected with the copper pipe, and the welding side is used. Method, the interface is strong and beautiful.

6、根据各用电电器性能配置导线,导线线径达到要求,接头牢固,需保护穿管则不能省,接电正确。导线进蒸发器接线盒孔,需硅胶密封,接灯如是36V电以上则需接地线,冷库机组电柜内进电需三相五线制,要有可靠接地。

6, according to the performance of each electrical appliance, the conductor diameter is up to the requirement, and the connection is firm. If the conductor is protected, it can not be saved and the power is properly connected. Wire into the evaporator junction box hole, the need for silica gel seal, the lamp if 36V electricity is to be connected to the ground wire, cold storage unit electric cabinet into the electric cabinet three phase five wire system, to have reliable grounding.

7、冷库机组温度显示探头穿入冷库内蒸发器回风口,且悬空,冷库机组化霜温度探头另穿孔入冷库内蒸发器回风口,探头插入翅片中(不能靠近电热管)。

7. The temperature display probe of the cold storage unit penetrates the evaporator back to the air outlet in the cold storage and is suspended, and the Frost temperature probe of the cold storage unit is penetrated into the evaporator back air outlet in the cold storage, and the probe is inserted in the fin (not near the electric heating tube).

8、平衡孔(均压阀,又叫做平衡窗),不要装在显眼处及出风口立板上,高度为冷库立板上部下来200MM开孔。所有贯穿冷库库板的部件,冷库库板与部件缝隙需用密封胶密封

8, balance hole (equalizing pressure valve, also called balance window), do not fit in the conspicuous place and the air outlet vertical plate. The height is the upper part of the cold storage vertical plate, and the 200MM hole is opened. All the components that run through the cold storage board, the seals for the cold store boards and components need to be sealed with sealant